Steam turbine labyrinth seals: wear, warning signs and when to replace

Seals are among the most “consumable” parts of a steam turbine. They do not fail suddenly like a blade or a bearing shell — they wear gradually, and a turbine can run for years with enlarged clearances. The plant pays for it with steam that bypasses the flow path and with water in the oil.

Where the seals are

A turbine has several groups of labyrinth seals:

  • Gland (end) seals — front and rear seals of the HP, IP and LP cylinders, where the shaft leaves the casing. On the high-pressure side they keep steam from escaping; on the LP cylinder of a condensing turbine they keep air out of the vacuum.
  • Diaphragm seals — between the shaft and the diaphragm of each stage. Leakage through them bypasses the nozzles.
  • Tip (shroud) seals — above the shrouds of the moving blades. Leakage through them bypasses the blades.

The principle is the same everywhere: a row of thin fins with a small radial clearance to the shaft. Steam passes through the gaps and chambers between them, loses pressure, and leakage stays small. The fins may be machined on segments held in a ring, or caulked into the shaft or into sleeves on the shaft. Segments are usually spring-backed: on contact they retract instead of cutting into the shaft.

Why they wear

  • Rubs during start-ups and vibration. Rotor bow from uneven warm-up, high vibration, casing distortion — the fins touch the shaft and are worn down. After that the clearance never comes back by itself.
  • Thermal expansion when start-up and shutdown procedures are not followed.
  • Erosion and corrosion — wet steam, salt deposits, idle periods without preservation.
  • Segments sticking in the ring grooves because of deposits: the springs stop working, and the next rub hits the shaft.

Signs of wear in operation

  • The gland seals leak more steam than before, and pressure in the seal chambers rises.
  • Water in the oil: steam from the front glands gets into the bearing housings.
  • Worse vacuum in condensing turbines — air is drawn in through worn LP rear glands.
  • Lower efficiency: more steam is needed for the same load, and stage pressures differ from earlier readings.

The real condition of the seals can only be seen when the turbine is opened: during a major overhaul the radial clearances are measured and the fins inspected.

Repair or replacement

If the fins are only slightly worn and the segments and rings are intact, the seals can be restored: the fins re-caulked and the segments fitted to clearance. If the fins are worn away, the segments are cracked or distorted, or the ring is damaged, the seal is replaced. New segments are fitted to the clearances in the turbine log, so it makes sense to order them in advance, before the casing is opened: there is no time to wait for delivery during an overhaul.

What to include in your request

  1. Turbine model — for example, Т-50-130, ПТ-50/60-130 or ВПТ-25.
  2. Which seal: front or rear, which cylinder, or the diaphragm seal of which stage.
  3. Drawing number if you have it — then the match is unambiguous. How to find it is explained in How to find a turbine part by drawing number.
  4. Number of segments or rings, and the main dimensions if there is no drawing number.

Our catalog lists steam turbine seals (HP, IP and LP gland seals, sealing rings) and, separately, centrifugal compressor seals. If the item you need is not listed, send us a request and we will match it using the manufacturer’s documentation.

All articles

Can’t find the part you need?

Send us the drawing number or a photo — we will find a substitute or manufacture it to the OEM documentation.