Impellers for Д, ДН and ВДН draft fans: wear and replacement

Induced draft (ID) and forced draft (FD) fans run at every boiler, and almost always without a standby. If an ID fan impeller goes out of balance or wears out, the boiler has to be unloaded or stopped. And an ID fan impeller wears faster than any other part of a draft fan.

How to read the designation

  • Д — induced draft fan, ДН — single-inlet induced draft fan with backward-curved blades, ВДН — forced draft fan of the same design.
  • The number is the impeller diameter in decimetres: ДН-12,5 has a 1250 mm impeller, Д-20 — about 2000 mm.
  • Extra digits and letters (for example ×2, “у”) indicate the version — double inlet, an upgraded design and so on.
  • Direction of rotation — right or left. Right-hand and left-hand impellers are not interchangeable.

Why impellers wear

  • Abrasive fly-ash wear. The main cause in ID fans. Fly ash erodes the blades and the back plate, especially at the inlet and the trailing edges. With poorly working ash collectors wear is many times faster.
  • Corrosion. If the flue gas temperature drops below the dew point, acidic moisture condenses on the impeller and eats the metal.
  • Build-up. Ash sticks unevenly — unbalance appears and vibration rises.
  • Cracks in the welds between blades and plates — from vibration and fatigue.
  • Loosening of the hub fit on the shaft.

Signs

  • vibration of the fan bearings rises, and balancing helps only for a short time;
  • capacity or furnace draft falls at the same load;
  • noise and knocking appear;
  • inspection shows worn-through blades and plates and cracks at the welds.

Repair or a new impeller

A moderately worn impeller is restored: the blades are hardfaced, wear liners are fitted, and the impeller is always balanced. But if wear is through, the plates are cracked or the impeller has already been repaired several times, a new one is cheaper and more reliable. A new impeller arrives balanced and serves its full life, while a hardfaced one often needs repair again after just one season.

If a boiler has only one ID fan, a spare impeller in stock saves a forced boiler shutdown for the duration of the repair.

What to include in your request

  1. Fan size: Д-15,5, ДН-12,5, ВДН-10, ГД 20-500 and so on.
  2. Direction of rotation — right or left, as stated in the data sheet or on the nameplate.
  3. Hub bore diameter and fit length, if the impeller goes onto an existing shaft.
  4. Drawing number if you have it, or photos of the impeller and the nameplate.