ЭнергомашремонтEletex representative office
Send a request

November 28, 2026 · 5 min read

Steam turbine governing system: which parts are replaced most often

The governing system holds turbine speed and load and the steam pressure at the extractions, and protects the machine from overspeed. Its parts are small and inexpensive compared with a rotor or a casing, but safety depends on them directly: a faulty overspeed trip or a sticking stop valve is a straight path to an overspeed failure.

What the system consists of

  • Speed governor — senses rotor speed and sends the signal to move the valves.
  • Pilot valves and servomotors — amplify the signal with pressurised oil and move the control valves.
  • Control valves — change the steam flow into the turbine or from the extractions.
  • Pressure regulators — hold the pressure in the process and heating extractions, or the back pressure. Their sensing element is often a diaphragm or a bellows.
  • Overspeed trip — bolts or rings that fly out under centrifugal force when speed is exceeded and trigger the protection.
  • Automatic stop valve — quickly shuts off steam to the turbine on a protection signal.

What wears

Pilot valve pairs. Worn edges and lands, scoring from dirty oil. Clearance grows, oil leaks appear and the governing becomes less sensitive. The spool and its sleeve work as a pair, so they are usually replaced together.

Regulator diaphragms and springs. Diaphragms age, lose elasticity and crack. Springs sag, and the regulator starts holding the wrong set point.

Overspeed trip bolts and springs. Wear, corrosion, a sticking bolt — the trip operates at the wrong speed or not at all. That is why it is regularly tested, as the operating rules require.

Stems, bushings and valves. Worn stems and guide bushings, salt deposits, sticking — the valve moves in jerks or does not seat tightly.

Oil deflectors and seals. Wear leads to oil leaks and lets dirt and steam into the oil system.

Signs of a fault

  • speed or load hunting with unchanged external conditions;
  • the turbine does not hold extraction pressure well, the regulator “floats”;
  • growing dead band: load changes in steps and jerks;
  • the overspeed trip operates at the wrong speed during a test;
  • the stop or control valve closes slowly or does not seal.

If the overspeed protection is faulty, the turbine must not be kept in service until the repair. Protection parts are best held in stock in advance.

What to include in your request

  1. Turbine model. Governing assemblies often differ between models, even closely related ones. Our catalog has the most items for АКВ-5…АКВ-18, ВКВ-18 and ВКВ-22, Т-30-90 and АР-6 machines.
  2. Assembly name as in the documentation: “pressure regulator 10–18 ata”, “governing block”, “overspeed trip”.
  3. Drawing number — especially important for governing parts: parts that look alike differ in stroke, springs and diameters.

Items are in the governing system parts section; stop and control valves are in the valves section. Can’t find it? Send a request and we will match it using the manufacturer’s documentation.

All articles

Can’t find the part you need?

Send us the drawing number or a photo — we will find a substitute or manufacture it to the OEM documentation.